cat8 penumbra catheter

    Do not use kinked or damaged devices. Penumbra introduced the Indigo System CAT RX in 2017 for the removal of fresh, soft emboli and thrombi from the coronary and peripheral vasculature. Launches Indigo System Lightning 12 in U.S. Appoints Corey L. Teigen, M.D., as Chief Scientific Officer and James F. Benenati, M.D., FSIR, as Chief Medical Officer Penumbra, Inc. (NYSE: PEN), a global healthcare company focused on innovative therapies, today announced its next phase for vascular franchise growth with U.S. commercial availability of the Indigo System Lightning 12 and . The Penumbra Indigo System Separator is intended for use with our Indigo Systems CAT family of catheters to enable the removal of a wide range of thrombus. The INDIGO SEPARATOR is not intended for use as a guidewire. At our institutions, we are using CAT RX for patients who present with fresh soft thrombi or emboli. Penumbra CAT8TORQ85 CAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral Thrombectomy Mechanical one each . The Penumbra ENGINE addresses the limitations of traditional treatment options by providing sustained mechanical power aspiration for the duration of the procedure to help maximize efficiency of thrombus removal. The cat8 was kinked approximately 69. The means of mains disconnect is to remove the power cord. The median aspiration time with CAT RX was 35 seconds, with no incidence of stroke within 30 days (Figure 2).3. left-arrow The procedure was completed with the same catheter. LIGHTNING Aspiration Tubing is a sterile aspiration tubing component of the INDIGO Aspiration System and is intended to serve as a conduit to assist in thrombus removal and restoration of blood flow in the peripheral vasculature and for the treatment of pulmonary embolism. Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide. sjaymathewsmd@gmail.com The Indigo System utilises the Penumbra ENGINE aspiration source capable of delivering nearly pure, continuous vacuum (-29 inHg or 98.2 kPa) to our catheters, enabling thrombus removal in vessels of various sizes. Placing guidewire too distal in the pulmonary vasculature or excessive manipulation of aspiration/guiding catheter in the smaller, peripheral, and segmental pulmonary artery branches can result in vessel perforation. Do not use kinked or damaged devices. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. The Indigo System CAT3, CAT5, CAT6, CAT8, CATD, and CAT7D are engineered to be robust, trackable, atraumatic, and well suited for the peripheral anatomy. Orange, California Do not advance, retract or use any component of the INDIGO System against resistance without careful assessment of the cause using fluoroscopy. It is intended for use in the revascularization of patients with acute ischemic stroke secondary to intracranial large vessel occlusions. Saxon RR, Benenati JF, Teigen C, et al. right-arrow Penumbra CAT8XTORQ115 CAT8 Indigo System Aspiration Catheter 8F Item Past Expiration +1(833)330-3033. Do not use open or damaged packages. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System. S. Jay Mathews, MD, MS, FACC As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 (Penumbra, Inc.) are indicated for the removal of fresh soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Penumbra System CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm - Non-Expired: 8Fr x 115cm 0: Contact Us: . N Engl J Med. INDIGO Aspiration Catheters and Separators: Penumbra System ACE 68 KIT Reperfusion Catheter & Penumbra Hi-Flow Aspiration Tubing - 6Fr x .068" x 132cm: 6Fr x .068" x 132cm $600.00. The Indigo Aspiration System should only be used by physicians who have received appropriate training in interventional techniques. In-Date Home; 3M KCI; Abbott; Acist; Acumed; Acutus; AD Surgical; Adhezion; Aesculap; Alcon Use prior to the Use By date. window.dataLayer = window.dataLayer || []; Penumbra's CAT family of catheters is engineered to be robust, trackable, atraumatic, and well suited to the peripheral anatomy where clots can form in long segments. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . Disclaimer: The opinions and clinical experiences presented herein are for informational purposes only. Penumbra has issued an urgent recall of all configurations of the Penumbra JET 7 Reperfusion Catheter with Xtra Flex Technology (JET 7 Xtra Flex) based on the risk of unexpected death or serious . After just one pass with CAT RX and 20 seconds of aspiration, the thrombus was removed. She had normal left ventricular systolic function with severe right ventricular dysfunction on her echocardiogram. If repositioning of the INDIGO CAT RX Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard guidewire techniques. gtag('js', new Date()); Mechanical power aspiration with the Indigo System CAT RX (Penumbra, Inc.), introduced in 2018, continues to gain in popularity as a solution for high thrombus burden in the coronaries. waqas.qureshi@umassmemorial.org function gtag(){dataLayer.push(arguments);} If the cause cannot be determined, withdraw the device or system as a unit. The initial angiogram revealed TIMI 0 flow in the proximal right coronary artery (RCA) due to plaque rupture. Initial experience with a mechanical aspiration catheter for thrombus removal during percutaneous intervention: a multicenter retrospective case series. University of Massachusetts Medical School Maintain a constant infusion of appropriate flush solution. Manual aspiration using a Pronto V3 (Teleflex) catheter restored some flow, however, distal embolization to the posterior descending artery (PDA) immediately caused right ventricular cardiac arrest (Figure 2). Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 inches (30 cm) to any part of the PENUMBRA ENGINE. The Indigo Separator 4 is not intended for use as a guidewire. Use of LIGHTNING Aspiration Tubing adjacent to other equipment should be avoided because it could result in improper operation. 1. Indigo Disposable Separator 8, 150 cm Length, 0.072 in. Prior to use, please consult device labeling and instructions for use. indicated to connect the INDIGO CAT RX Aspiration Catheters to the Penumbra Aspiration Pump. Possible complications include, but are not limited to, the following: No modification of this equipment is allowed. Pinterest; CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm Penumbra System) Model #: CAT8XTORQ115KIT OEM: Penumbra System Expiration Date: 2022 Size : 8Fr x 115cm . Pela bainha, foi introduzido o dispositivo de aspirao Penumbra Indigo System CAT8 XTORQ (Penumbra Inc., Alameda, Califrnia, Estados Unidos) em trombo segmentar, lobar ou arterial pulmonar principal, sendo realizada aspirao contnua (Figuras 2 e 3). The Indigo System CAT RX with Penumbra ENGINE is an invaluable tool that is easy to set up and can provide rapid thrombectomy and immediate reperfusion. Do not use in oxygen rich environment. Tareq Kass-Hout. The penumbra cat8 indigo system (cat8) was kinked approximately 4. The Penumbra P logos, 3D, 3D Revascularization Device, ACE, BENCHMARK, CAT, Indigo, LANTERN, MAX, Neuron, Neuron MAX, Penumbra ENGINE, Penumbra JET, Penumbra System, Penumbra SMART COIL, POD, Ruby, Separator, Velocity, and WAVE are registered trademarks or trademarks of Penumbra, Inc. in the USA and other countries. When performing aspiration, ensure that the INDIGO Aspiration Tubing valve is open for only the minimum time needed to remove thrombus. Lightning Aspiration Tubing has dual pressure sensors for real-time blood flow monitoring. In a retrospective analysis of patients in our practice with fresh thrombus burden, we have observed TIMI 3 restored when using CAT RX frontline.1 This is another positive patient outcome with the use of CAT RX in a case of high thrombus burden. Tip directionality for circumferential aspiration, Live feedback during procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposablePenumbra ENGINE Canister. Figure 2. The Indigo System CAT RX was the preferred choice for mechanical aspiration thrombectomy to remove the distal emboli below the knee in the posterior tibial artery. Return all damaged devices and packaging to the manufacturer/ distributor. . The Indigo System CAT3, CAT5, CAT6, CAT8, CATD, and CAT RX are engineered to be robust, trackable, atraumatic, and well suited for the peripheral anatomy. Copyright 2022 Penumbra, Inc. All rights reserved. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove the thrombus. Penumbras IndigoAspiration System can be used to remove emboli and thrombi from vessels of the peripheral arterial and venous systems, and for treatment of pulmonary embolism. Unit may overheat and shut off or fail to restart if run for extended periods without airflow. Penumbra ENGINE Intended Use Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia; arteriovenous fistula; cardiac injury; cardio-respiratory arrest; death; device malfunction; distal embolization; emboli; excessive blood loss; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; hemoptysis; respiratory failure; thromboembolic events. Only use replacement fuse with correct rating (see Table 1 for fuse rating). Gus Theodos, MD, FACC, FSCAI Use the Indigo Aspiration System in conjunction with fluoroscopic visualization. The Indigo Aspiration System is intended for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and certain central circulatory system conditions such as pulmonary emboli using continuous aspiration. INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 Indication for Use As part of the INDIGO Aspiration System, the INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove thrombus. Due to continual vomiting, an electrocardiogram was obtained that showed an acute MI. infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Control angiography immediately after thrombectomy demonstrated restored patency . Interventional therapies for acute pulmonary embolism: current status and principles for the development of novel evidence: a scientific statement from the American Heart Association. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. $399.00 EACH. The patient had a medical history of cyclical vomiting, hypertension, diabetes, and hyperlipidemia. Penumbra CAT8 KIT Indigo Aspiration Catheter 8 & Aspiration Tubing, XTorq Tip 115cm x 8F (NON-STERILE) Expired. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Most recently, Penumbra launched LP System, including Ruby Coil LP and Packing Coil LP, which are low profile microcatheter compatible (.0165 - .021 ID). The sustained aspiration power provided by the Penumbra ENGINE allowed rapid TIMI 3 flow restoration and removal of the distal emboli. $450.00) Model #: CAT8TORQ85 OEM: Penumbra System Expiration Date: 2022 Size: 8Fr x 85cm . The newly available Indigo CAT12 Aspiration Catheter (Penumbra, Inc.) was utilized to perform mechanical thrombectomy of the FV, CFV, and EIV and CIV without the use of thrombolytics . There was an immediate response in the clinical situation of the patient: her blood pressure stabilized into the 90s and her oxygenation improved substantially. The CAT familyof catheters is the foundation of Penumbras Indigo System. Caution: Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. Equipment is not safe for MR use. The built-in microprocessor features a proprietary thrombus removal algorithm that automatically controls a valve in the tubing to provide continuous or intermittent aspiration. The newest indication for the Indigo System is the treatment of pulmonary embolism; this indication comes on the heels of the promising results of the EXTRACT-PE trial. Do not use in oxygen rich environment. Do not use kinked or damaged devices. Disclosures: Consultant to Penumbra, Inc. A 92-year-old man with a history of coronary artery disease (treated previously with coronary artery bypass graft) and severe aortic stenosis (treated previously with transcatheter aortic valve replacement) presented to the ED with chest pain. Get Penumbra Cat 8 in Secunderabad, Hyderabad, Telangana at best price by Zephyr Technologies. chronic clot, atherosclerotic plaque) Enter your email address and we will contact you. Return all damaged devices and packaging to the manufacturer/distributor. Penumbra ENGINE Intended Use Contraindications There are no known contraindications. The Indigo System with Lightning Aspiration Tubing is a computer-aided aspiration system powered by Penumbra ENGINE. Aspiration or disruption of thrombus with traditional diminished syringe-based aspiration or other mechanical devices is difficult, often incomplete, and has been associated with high complication rates.1 Use of medical therapy, such as powerful anticoagulants and thrombolytics (ie, tissue plasminogen activator), may carry a high risk of bleeding.2 The Indigo System was designed to provide sustained aspiration with Penumbra ENGINE to effectively remove thrombus, while reducing the risk of bleeding complications.3 The Indigo System utilizes atraumatic catheters varying in diameters from 3.4 to 8 F and lengths ranging from 50 to 150 cm. gtag('config', 'UA-18982160-1'); Penumbra Inc .cls-1{fill:#a6a699;}.cls-2{fill:#b5121b;}.cls-3{isolation:isolate;fill:url(#linear-gradient);}. She was in a rehab facility prior to this new event recovering from her CVA. Mechanical thrombectomy was performed. The atraumatic, low-profile design of CAT RX allowed for ease of deliverability through the freshly placed stent into the PDA when the patient was in critical condition. With automatic valve control, Lightning can help the physician focus on optimising thrombus removal procedures. Its engineers designed low-profile, high-power aspiration catheters called Cat 7 and Cat 12 that were launched in 2021. It will reduce service life of the Penumbra ENGINE. CAT RX mechanical aspiration system powered by Penumbra ENGINE in comparison to manual syringe-based aspiration. The patient was brought back to the cardiac cath lab for follow-up angiography that revealed TIMI 0 flow of the RCA (Figure 1). Indigo System CAT RX tracking through the distal posterior tibial artery. The built-in microprocessor features a proprietary thrombus removal algorithm that automatically controls a valve in the tubing to provide continuous or intermittent aspiration. The Indigo System CAT RX and Penumbra ENGINE aspiration source were crucial to the success of this case. There was partial improvement of flow, but total occlusion remained.

    Stone Brick Wall Hypixel Skyblock, Articles C

    Comments are closed.